We are a leading Biosafety Cabinet Manufacturers in Chennai, All model Biosafety Cabinets such as Class II Type A1, Class II Type A2, Class II Type B1, Class II Type B2, Class III are available.
1, Biosafety Cabinet – Class II Type A1
“Pureair” Biosafety Cabinet Class II Type A1 is designed for protection of operator, product and environment from pathogenic agents and microorganisms transmitted in respiratory way and also for creation of a bacterial dust free air environment. It has a common plenum from which 30% of air is exhausted, and 70% re-circulated to the work area as the downflow. Type A cabinets exhaust air directly back to the laboratory, and they may contain positive pressure contaminated plenums. When toxic chemicals must be employed as an adjunct to microbiological processes, these cabinets should not be used. Exhaust HEPA filtration only removes airborne aerosols including biohazards, and not chemical fumes.
The Class II Type A1 has the positively-pressurized contaminated plenum bordering the ambient environment, and therefore is less safe than the Class II Type A2 that has a negative pressure surrounding the positively pressurized contaminated plenum. In case there is a leakage on the positive plenum, the leaking aerosol will be pulled by the negative pressure back to the positive plenum, and it will not leak out. Because of the safety issue, the Type A1 design is now considered obsolete. In the A1 cabinet, about 70% of air from the positive plenum is recirculated as downflow, and the remaining All Class II biological safety cabinets type A1 is suitable for work with microbiological agents assigned to biosafety levels 1, 2 and 3.
Working Area – Stainless Steel IS 304 Grade Satin Finish
| Product | Biosafety Cabinet – Class II- Type A1 |
|---|---|
| Air balancing | 70% recirculation, 30% exhaust |
| Protection | Product, Personnel & Environmental protection |
| Cleanliness Level | ISO Class 5 as per ISO 14644-1 |
| Average Airflow |
Inflow Velocity: Minimum 0.45 m/s (90 FPM) at 8” front opening Downflow Velocity: 0.30 m/s (65 FPM) |
| Noise Level | 60 dB on A scale |
| Light Intensity | Minimum 900 lux inside the working area at ambient zero |
| MOC |
Main Body – Galvanized Iron with PU coated / Stainless Steel – Satin Finish Working Area – Stainless Steel IS 304 Grade Satin Finish |
| Supply Filter |
HEPA Filter having EU 13 rating with suitable size. Efficiency: 99.99% down to 0.3 Microns. |
| Exhaust Filter |
HEPA Filter having EU 13 rating with suitable size. Efficiency: 99.99% down to 0.3 Microns. |
| Pre Filter |
“Pureair” Make – EU 4 Rating with suitable size. Efficiency: 90% down to 10 Microns. |
| Noise Level | Less than 70 dB ‘A’ |
| Vibration Level | Minimum |
| Magnehelic Differential Pressure Gauge | 01 No. (Make: Dwyer, USA) – To measure differential pressure across the supply HEPA filter. |
| Motor Blower Assembly |
Statically & Dynamically balanced with suitable rating and size. Induction motor with centrifugal blower. Mounting: Unique spring suspension system to reduce vibration & noise. |
| 3 Pin Switch & Socket | 15 AMPS – 1 set in each unit |
| Other Switches | On/Off switches for motor blower & CFL lights |
“Pureair” Biosafety Cabinet Class II Type A2 is designed for protection of operator, product and environment from pathogenic agents and microorganisms transmitted in respiratory way and also for creation of a bacterial dust free air environment. It has a common plenum from which 30% of air is exhausted, and 70% re-circulated to the work area as the down flow. Type A cabinets exhaust air directly back to the laboratory, and they may contain positive pressure contaminated plenums. When toxic chemicals must be employed as an adjunct to microbiological processes, these cabinets should not be used. Exhaust HEPA filtration only removes airborne aerosols including biohazards, and not chemical fumes.
The Class II Type A1 has the positively-pressurized contaminated plenum bordering the ambient environment, and therefore is less safe than the Class II Type A2 that has a negative pressure surrounding the positively pressurized contaminated plenum. In case there is a leakage on the positive plenum, the leaking aerosol will be pulled by the negative pressure back to the positive plenum, and it will not leak out. Because of the safety issue, the Type A1 design is now considered obsolete. In the A2 cabinet, about 70% of air from the positive plenum is recirculated as down flow, and the remaining All Class II biological safety cabinets A2 is suitable for work with microbiological agents assigned to biosafety levels 1, 2 and 3.
| No. | Property | Details |
|---|---|---|
| 1 | Product | Class II Biosafety Cabinet – Type A2 |
| 2 | Air balancing | 70% recirculation, 30% exhaust |
| 3 | Protection | Product, Personnel & Environmental Protection |
| 4 | Bio safety Level | Bio Safety Level 1, 2 & 3 |
| 5 | Exhaust Requirement | Return to Laboratory or Thimble Ducting Only |
| 6 | Cleanliness Level | ISO Class 5 as per ISO 14644-1 |
| 7 | Average Airflow | Inflow Velocity Minimum 0.45 m/s (90 FPM) at 8” front opening |
| 8 | Velocity | Down Velocity 0.30 m/s (65 FPM) |
| 9 | Noise Level | 60 dB on A scale |
| 10 | Light Intensity | Minimum 900 lux inside the working area at ambient zero |
| 11 | MOC | Main Body – Galvanized Iron with PU coated / Stainless Steel – Satin Finish Working Area – Stainless Steel IS 304 Grade Satin Finish |
| 12 | Supply Filter | HEPA Filter having EU 13 rating with suitable size. Efficiency 99.99% down to 0.3 Microns. |
| 13 | Exhaust Filter | HEPA Filter having EU 13 rating with suitable size. Efficiency 99.99% down to 0.3 Microns. |
| 14 | Pre Filter | “Pureair” make, EU 4 rating with suitable size. Efficiency 90% down to 10 Microns. |
| 15 | Noise Level | Less than 70 dB ‘A’ |
| 16 | Vibration Level / Instrumentation | Minimum |
| 17 | Magnehelic Differential Pressure Gauge | 01 No. (Make: Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter). |
| 18 | Motor Blower Assembly | Statically & Dynamically balanced with suitable rating and size. (Induction motor with centrifugal blower) Mounted on unique spring suspension system to reduce vibration and noise. |
| 19 | 3 Pins Switch & Socket | 15 AMPS – 1 set in each unit |
| 20 | Other Switches | On/Off switches for motor blower & CFL lights |
| PAH 600 | PAH 900 | PAH 1200 | PAH 1800 | |
|---|---|---|---|---|
| Horizontal | PAH 600 | PAH 900 | PAH 1200 | PAH 1800 |
| Vertical | PAV 600 | PAV 900 | PAV 1200 | PAV 1800 |
| Working Size | 2 x 2 x 2 | 3 x 2 x 2 | 4 x 2 x 2 | 6 x 2 x 2 |
“Pureair” Biosafety Cabinet Class II Type B1 has a common plenum from which 70% of air is exhausted, and 30% re-circulated to the work area as the down flow.
Type B1 cabinets also have a dedicated exhaust feature that eliminates re-circulation when work is performed towards the back within the interior of the cabinet. Toxic chemicals employed as an adjunct to microbiological processes should only be employed if they do not interfere with work when re-circulated in the down flow.
| No. | Property | Details |
|---|---|---|
| 1 | Product | Bio Safety Cabinet – Class II Type B1 |
| 2 | Air Balancing | 30% recirculation, 70% exhaust |
| 3 | Protection | Product, Personnel & Environmental protection |
| 4 | Bio Safety Level | Bio Safety Level 1, 2 & 3 |
| 5 | Exhaust Duct Requirement | Hard Duct Only |
| 6 | Control Plenum Surrounded By | Negative Plenum |
| 7 | Cleanliness Level | ISO Class 5 as per ISO 14644-1 |
| 8 | Average Airflow / Velocity |
Inflow Velocity – Minimum 0.45 m/s (90 FPM) at 8” front opening Downflow Velocity – 0.30 m/s (65 FPM) |
| 9 | Noise Level | 60 dB on A scale |
| 10 | Light Intensity | Minimum 900 lux inside the working area at ambient zero |
| 11 | MOC |
Main Body – Galvanized Iron with PU coated / Stainless Steel – Satin Finish Working Area – Stainless Steel IS 304 Grade Satin Finish |
| 12 | Supply Filter |
HEPA Filter having EU 13 rating with suitable size. Efficiency: 99.99% down to 0.3 Microns. |
| 13 | Exhaust Filter |
HEPA Filter having EU 13 rating with suitable size. Efficiency: 99.99% down to 0.3 Microns. |
| 14 | Pre Filter |
“Pureair” make, EU 4 rating with suitable size. Efficiency: 90% down to 10 Microns. |
| 15 | Noise Level | Less than 70 dB ‘A’ |
| 16 | Vibration Level / Instrumentation | Minimum |
| 17 | Differential Pressure Gauge |
Magnehelic Gauge – 01 No. (Make: Dwyer, USA) with each unit (To measure differential pressure across the supply HEPA filter) |
| 18 | Supply & Exhaust Motor Blower Assembly |
Statically & Dynamically balanced with suitable rating and size. Induction motor with centrifugal blower. Mounted on unique spring suspension system to reduce vibration and noise. |
| 19 | 3 Pins Switch & Socket | 15 AMPS – 1 set in each unit |
| 20 | Other Switches | On/Off switches for motor blower & CFL lights |
| 21 | Microprocessor Control |
Airflow Display UV Interlocking Low Airflow Alarm Supply & Exhaust Filter Fail Indication |
“Pureair” Biosafety Cabinet Class II Type B2 all inflow and downflow air is exhausted after HEPA filtration to the external environment without recirculation within the cabinet. Type B2 cabinets are suitable for work with toxic chemicals used in microbiological processes since no re-circulation occurs. They are among the safest Class II cabinets but difficult to install, balance, and maintain.
| 1 | Product | Biosafety Cabinet – Class II Type B2 |
|---|---|---|
| 2 | Air Balancing | 0% recirculation, 100% exhaust |
| 3 | Protection | Product, Personnel & Environmental Protection |
| 4 | Biosafety Level | BSL 1, 2 & 3 |
| 5 | Exhaust Duct Requirement | Hard Duct Only |
| 6 | Control Plenum | Negative Plenum |
| 7 | Cleanliness Level | ISO Class 5 (ISO 14644-1) |
| 8 | Average Airflow Velocity |
Inflow: Minimum 0.45 m/s (90 FPM) at 8” front opening Downflow: 0.30 m/s (65 FPM) |
| 9 | Noise Level | 60 dB(A) |
| 10 | Light Intensity | Minimum 900 lux |
| 11 | MOC |
Main Body: GI with PU coated / SS Satin Finish Working Area: SS 304 Satin Finish |
| 12 | Supply Filter | HEPA EU13, 99.99% @ 0.3 microns |
| 13 | Exhaust Filter | HEPA EU13, 99.99% @ 0.3 microns |
| 14 | Pre Filter | EU4, 90% @ 10 microns |
| 15 | Noise Level | < 70 dB(A) |
| 16 | Vibration Level | Minimum |
| 17 | Differential Pressure Gauge |
Magnehelic Gauge (Dwyer, USA) Measures HEPA differential pressure |
| 18 | Motor Blower Assembly | Centrifugal blower with spring suspension |
| 19 | Switch & Socket | 15A, 3-pin |
| 20 | Switches | On/Off for blower & lights |
| 21 | Microprocessor Control | Airflow display, UV interlock, alarms |
“Pureair” Biosafety Cabinet Class III ensures absolute safety with fully gas-tight construction. Work is performed using glove ports. The cabinet maintains negative pressure to prevent leaks. HEPA supply and double HEPA exhaust filtration ensure total containment. Suitable for BSL 1–4 including high-risk pathogens.
| 1 | Product | Biosafety Cabinet – Class III |
|---|---|---|
| 2 | Air Balancing | 0% recirculation, 100% exhaust |
| 3 | Protection | Product, Personnel & Environmental Protection |
| 4 | Biosafety Level | BSL 1, 2, 3 & 4 |
| 5 | Exhaust Duct Requirement | Inside room / Hard duct only |
| 6 | Control Plenum | Negative Plenum |
| 7 | Cleanliness Level | ISO Class 5 (ISO 14644-1) |
| 8a | Negative Pressure | > 0.5" WC (closed chamber) |
| 8b | Front Sash | Airtight with Glove Port |
| 9 | Noise Level | 60 dB(A) |
| 10 | Light Intensity | Minimum 900 lux |
| 11 | MOC |
Main Body: GI PU coated / SS Satin Finish Working Area: SS 304 Satin Finish |
| 12 | Supply Filter | HEPA EU13, 99.99% @ 0.3 microns |
| 13 | Exhaust Filter (Double) | Double HEPA EU13, 99.99% @ 0.3 microns |
| 14 | Pre Filter | EU4, 90% @ 10 microns |
| 15 | Noise Level | < 70 dB(A) |
| 16 | Vibration | Minimum |
| 17 | Differential Pressure Gauge | Magnehelic Gauge (Dwyer, USA) |
| 18 | Motor Blower Assembly | Centrifugal blower with spring suspension |
| 19 | Switch & Socket | 15A, 3-pin |
| 20 | Switches | On/Off for blower & lights |
| 21 | Microprocessor Control | Airflow display, UV interlock, alarms |